American Standard 2425L / V Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Nie American Standard 2425L / V. American Standard 2425L / V Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 56
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
P.O. Box 309
Mt. Pleasant, MI 48804-0309
Tele: 989•773•9100
Fax: 989•772•3415
Visit us on the web at milansupply.com
Pumps
Orenco
Myers
Goulds
Sta-Rite
Delta
Wastewater Treatment
Orenco
Bio Microbics
Eljen
Electrical Controls
Orenco
SJE Rhombus
ITT Goulds
Pentair
Milan Supply Company is known for the company we keep . . .
. . . and the products we carry
Contact Milan Supply Company for your Wastewater Needs
Specialty Equipment
•Inltrator Leach Fields
Pump Basins
Distribution Boxes
Guide Rail Systems
Dispersal Technologies
Access Doors
•Efuent Filters
Valves
Gate
Ball
Paddle
Hydrotek
Bull Run
Swing Check
Ball Check
PVC Pipe & Fittings
• Sch 40/80 PVC Pipe & Fittings
• DWV Pipe & Fittings
• Sewer & Drain Pipe & Fittings
Complete Systems
• Efuent Pump Systems
Sewage Pump Systems
Grinder Systems
Revision #08
Milan Supply Company’s reputation is based on quality products, competitive
prices, and dedication to outstanding service.
Product lines that encompass Wastewater Pumps and Accessories,
Control Panels, Wastewater Treatment Systems and Dispersal Field
accessories, point to our commitment to the industry.
Milan Engineered Systems, a division of Milan Supply Company, focuses
on the water resource markets. Milan Engineered Systems, partners with
Health Departments, Designers and Contractors to nd solutions for
Transport, Treatment and Dispersal of Onsite Wastewater.
Contact Milan for your wastewater system needs.
Location Address Phone Number Fax Number
Mt. Pleasant 7125 E. Pickard 1•800•756•4526 1•989•772•3415
Grayling 4603 Hanson Street 1•800•934•7867 1•989•348•7605
Indian River 6031 S. Straits Highway 1•800•856•4658 1•231•238•9776
Traverse City 6986 US31 S. 1•877•786•7867 1•231•276•6147
Sparta 9680 Sparta Avenue 1•800•790•7867 1•616•887•7037
Howell 4950 Mason Rd. 1•888•891•7851 1•517•552•1706
Visit us on the web at milansupply.com
Milan’s Wastewater Handbook
Milan’s Wastewater Handbook
Revision #08
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - Milan’s Wastewater Handbook

P.O. Box 309Mt. Pleasant, MI 48804-0309Tele: 989•773•9100Fax: 989•772•3415Visit us on the web at milansupply.comPumps • Orenco • Myers • Goul

Strona 2 - Table of Contents

Page 10Milan Supply Company/Milan Engineered SystemsSPECIFICATIONS:Solids Handling Capacity- 2”Intermittent Liquid Temp.- 140ºFDischarge (NPT)- 2”,

Strona 3 - Locations Across the State

Milan Supply Company/Milan Engineered SystemsPage 11Features and Bene ts • Wide-angle, mercury-free mechanical  oat switch for maximum draw down. •

Strona 4 - EFFLUENT PUMPS

Page 12Milan Supply Company/Milan Engineered SystemsMYERS SYSTEM BENEFITS • Eliminate guesswork of selecting components• No mismatched or improperl

Strona 5 - 10’ 25’ 50’ 60’ 80’ 100’ 120

Milan Supply Company/Milan Engineered SystemsPage 134” x 150’ Slotted Coil (150) CUL945004” x 150’ Slotted Coil W/Sock (150) CUL945054” x 150’ Solid C

Strona 6

Page 14Milan Supply Company/Milan Engineered SystemsAdvanTex® Treatment Systems are the ideal solution for secondary treatment of residential wastewat

Strona 7

Milan Supply Company/Milan Engineered SystemsPage 15

Strona 8 - Sewage Pumps

Page 16Milan Supply Company/Milan Engineered SystemsAll Orenco pump packages have these basic components: • Biotube® pump vault • Splice box • F

Strona 9

Milan Supply Company/Milan Engineered SystemsPage 17-76"!32Call for more information or a brochure • 989-773-9100Pump It Up!0RO34%0©%FFLUENT0UM

Strona 10 - SEWAGE PUMPS

Page 18Milan Supply Company/Milan Engineered SystemsSV1548-16 Low Head Screened Pump Vault SEW20000PVU57-2419L Biotube Vault 57” Deep SEW20010PVU68-2

Strona 11

Milan Supply Company/Milan Engineered SystemsPage 19 Tank & Pump Speci cations Tank Volume ________________ Tank Elevations: Riser Lid _______

Strona 12

PRODUCTS MANUFACTURER PAGEACCESS DOORS 24ALARMS SJE-RHOMBUS 30, 31,32BASINS JACKEL 24BULL RUN VALVES AMERICAN 42CARBON FILTERS ORENCO 42COMPRESSION

Strona 13 - Sta-Rite Pumps

Page 20Milan Supply Company/Milan Engineered SystemsS Series Simplex Control Panels Simplex control panels can be used for pressure sewer (STEP) syste

Strona 14

Milan Supply Company/Milan Engineered SystemsPage 21TABLE 31. CONTROL PANEL FEATURE/BENEFIT DESCRIPTIONS Option Bene tIR (intrinsically

Strona 15

Page 22Milan Supply Company/Milan Engineered SystemsOrenco Custom Panel Quote RequestCustomer EngineerCompany:Your name:Phone:Fax:Address:Email:Engine

Strona 16

Milan Supply Company/Milan Engineered SystemsPage 23 Complete Low Pressure Sewer Systems Options • Flex Hose or Rail System Available • Simple

Strona 17 - Pump It Up!

Page 24Milan Supply Company/Milan Engineered SystemsBasin 18 x 24 SF-22A SEW14005LId 18” Split SEW1402018x30 Basin Complete SEW14028Basement Sump 24”

Strona 18

Milan Supply Company/Milan Engineered SystemsPage 25��✔� � �� � � � � �� �� � � � �����

Strona 19

Page 26Milan Supply Company/Milan Engineered Systems

Strona 20

Milan Supply Company/Milan Engineered SystemsPage 27

Strona 21 - Option Bene t

Page 28Milan Supply Company/Milan Engineered Systems30”

Strona 22 - © 2007 Orenco Systems, Inc

Milan Supply Company/Milan Engineered SystemsPage 29StormTech chambers are an excellent alternative for Retention Detention systems. The chambers are

Strona 23 - Low Pressure Sewer Systems

Milan Supply Company/Milan Engineered SystemsPage 3Milan Supply Company / Milan Engineered Systems is proud to present “Milan’s Wastewater Handbook”.

Strona 24 - Jackel Basins

Page 30Milan Supply Company/Milan Engineered SystemsThe Tank Alert® XT indoor/outdoor alarm system monitors liquid level conditions in lift pump chamb

Strona 25

Milan Supply Company/Milan Engineered SystemsPage 31MODEL 112 Control PanelSingle phase, simplex motor contactor control.The Model 112 control panel p

Strona 26

Page 32Milan Supply Company/Milan Engineered SystemsPanel Simplex 115V 2 Float (MICH CP11-208) SEW10015Panel Simplex 115V 3 Float (MICH CP11-208E) S

Strona 27

Milan Supply Company/Milan Engineered SystemsPage 33Pump and AlarmPump Or AlarmPump DifferentialSimplex Float ArrangementsDuplex Float ArrangementsOff

Strona 28

Page 34Milan Supply Company/Milan Engineered SystemssWWWBIOMICROBICSCOM4OLEARNMOREABOUTOURCOMPLETELINEOFWASTEWATERTRANSFE

Strona 29

Milan Supply Company/Milan Engineered SystemsPage 35 Valves1” PVC Check Valve SxS KBI SEW222401.25” PVC Check Valve SxS KBI SEW222501.50”

Strona 30

Page 36Milan Supply Company/Milan Engineered SystemsPVC Pressure Fittings - Schedule 403/4” PVC05015 1” PVC05020 1.25” PVC05025 1.5” PVC05030 2” PVC05

Strona 31 - MODEL 122 Control Panel

Milan Supply Company/Milan Engineered SystemsPage 373/4” 850-0071” 850-0101.25” 850-0121.5” 850-0152” 850-0202.50” 850-0253” PVD180034” 850-040 Elbow

Strona 32

Page 38Milan Supply Company/Milan Engineered SystemsPVC PIPEPVC Sch80 X 20’ P.E.1.50” PVD000122” PVD00016 3” PVD000244” 4”X20’ Sch80 PE PVC Sch40

Strona 33 - Duplex Float Arrangements

Milan Supply Company/Milan Engineered SystemsPage 39Size O.D. Min. Wall PSI.5” .840 .062 315.75” 1.050 .060 2001” 1.315 .063 2001.25” 1.660 .079 2001.

Strona 34 - A#HANGING7ORLD

Page 4Milan Supply Company/Milan Engineered SystemsSPECIFICATIONS• Discharge size: 1 12” NPT.• Temperature: 104ºF (40ºC) maximum, • Solids handling:

Strona 35

Page 40Milan Supply Company/Milan Engineered SystemsModel Inlet Size (in) Outlet Size (in) Flow Range (gpm)V4000 1.25 1.25 10-40V6000 1.5 1.5 15-60The

Strona 36

Milan Supply Company/Milan Engineered SystemsPage 41

Strona 37

Page 42Milan Supply Company/Milan Engineered SystemsDistribution BoxesValve Boxes7” Valve Box W/Cover SEW1620010” Valve Box W/Cover SEW1621012” x 17”

Strona 38 - PVC PIPE

Milan Supply Company/Milan Engineered SystemsPage 43 Tank Width Tank Length 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 5 12.46

Strona 39

Page 44Milan Supply Company/Milan Engineered SystemsGPM 18” 24” 30” 36” 48”20 x x x x x25 x x x x x30 x x x x x35 x x x x x40 x x x x45 x x x x50 x x

Strona 40 - Pressure Indexing Zone Valve

Milan Supply Company/Milan Engineered SystemsPage 45FRICTION LOSS CHART FRICTION LOSS PER 100 FEET OF PIPE OF PLASTIC PIPE PIPE DIAMETER 1/2 in. 3/4

Strona 41

Page 46Milan Supply Company/Milan Engineered Systems300 Gal Septic Tank SEP96000500 Gal Poly Tank SEP96020750 Gal Septic Tank SEP960301000 Gal Tank SE

Strona 42 - Drain eld Supplies

Milan Supply Company/Milan Engineered SystemsPage 47

Strona 43 - q Pump and Dump

Page 48Milan Supply Company/Milan Engineered SystemsCOMMON EFFLUENT FILTER QUESTIONSWhat is a septic tank?The septic tank is the  rst component in a

Strona 44 - Fractional Conversion Chart

Milan Supply Company/Milan Engineered SystemsPage 49Model Inv. # GPDA1801 4 x 22 Ef uent Filter Cartridge SEW15005 500A1800C 4 X 22 VT-B35 Filter W/C

Strona 45 - FRICTION LOSS CHART

Milan Supply Company/Milan Engineered SystemsPage 5SPECIFICATIONS• Solids handling capabilities: 34” maximum.• Discharge size: 2” NPT.104°F (40°C) co

Strona 46 - DekoRRa Products

Page 50Milan Supply Company/Milan Engineered Systems• Porous Top of the Eljen GSFallows evapotranspiration andoxygen exchange for bettereffluent treat

Strona 47

Milan Supply Company/Milan Engineered SystemsPage 51In ltrator Chamber Systems EQ-36 22” Width 8.5’ Length CHA17000EQ-36 End-Plate 6” Invert CHA17007

Strona 48

Page 52Milan Supply Company/Milan Engineered SystemsNAME PHONESITE ADDRESS PHONEPHONEMAILING ADDRESS (If Different)DATE Sun Mon Tue Wed Thur Fri Sat T

Strona 49 - Ef uent Filters

Milan Supply Company/Milan Engineered SystemsPage 5320. TYPE OF SYSTEM: GRAVITY / GRAVITY WITH PUMP / PD / MOUND / SAND FILTER / ATU OTHER21. CONTROL

Strona 50 - D-Box or serial distribution

Page 54Milan Supply Company/Milan Engineered SystemsNOTES:Your answer to- Small lots- Poor soils- Irregular shaped lots- Shallow soils- Steep slopes.-

Strona 51 - In ltrator Chamber Systems

PRODUCTS MANUFACTURER PAGEACCESS DOORS 24ALARMS SJE-RHOMBUS 30, 31,32BASINS JACKEL 24BULL RUN VALVES AMERICAN 42CARBON FILTERS ORENCO 42COMPRESSION

Strona 52 - EVALUATION CHECKLIST

P.O. Box 309Mt. Pleasant, MI 48804-0309Tele: 989•773•9100Fax: 989•772•3415Visit us on the web at milansupply.comPumps • Orenco • Myers • Goul

Strona 53

Page 6Milan Supply Company/Milan Engineered SystemsSPECIFICATIONS - Pump:• Solids handling capabilities: 2” maximum.• Discharge size: 2” NPT.• Tempera

Strona 54 - DRIP DISPERSAL

Milan Supply Company/Milan Engineered SystemsPage 7 Model HP Shut Off5’ 10’ 15’ 20’ 25’ 30’ 35’PS51 .5 27’ 127 105 75 40 10WW05BF .5 18’ 63 27WS03BF

Strona 55

Page 8Milan Supply Company/Milan Engineered SystemsSump Pumps• Battery back-up sump pump for emergencies • 1/3 HP pedestal pumps• 1/4 HP through 4/10

Strona 56

Milan Supply Company/Milan Engineered SystemsPage 9SPECIFICATIONS:Solids Handling Capacity- 3/4”Intermittent Liquid Temp.- 140ºFDischarge (NPT)- 1 1/2

Komentarze do niniejszej Instrukcji

Brak uwag